Back to top
08045476196
Send SMS Send Inquiry


2 Way Pneumatic Actuator Operated Cryogenic Ball Valve
2 Way Pneumatic Actuator Operated Cryogenic Ball Valve

2 Way Pneumatic Actuator Operated Cryogenic Ball Valve

MOQ : 1 Set

2 Way Pneumatic Actuator Operated Cryogenic Ball Valve Specification

  • Structure
  • Ball Valve
  • Material
  • Stainless Steel (CF8M/SS316) Cryogenic Grade
  • Power
  • Pneumatic
  • Pressure
  • Up to 20 bar (290 psi)
  • Media
  • Gas, Liquid
  • Port Size
  • inch to 8 inch (DN15DN200)
  • Surface
  • Polished / Cleaned for Cryogenic Service
  • Shape
  • 2 Way
  • Application
  • Cryogenic Liquids, LNG, Liquid Nitrogen, Oxygen, Argon
 

2 Way Pneumatic Actuator Operated Cryogenic Ball Valve Trade Information

  • Minimum Order Quantity
  • 1 Set
  • Supply Ability
  • 1000 Sets Per Day
  • Delivery Time
  • 1 Days
 

About 2 Way Pneumatic Actuator Operated Cryogenic Ball Valve

2 Way Pneumatic Actuator Operated Cryogenic Ball Valve

Leveraging on our skilled professionals, we are able to provide the premium quality 2 Way Pneumatic Actuator Operated Cryogenic Ball Valve. This valve is ideal for trouble free flow of liquids and gases in several industries. The offered valve is manufactured by our dexterous professionals using pristine quality raw materials and avant-garde techniques. Beside this, our global clients can purchase this 2 Way Pneumatic Actuator Operated Cryogenic Ball Valve from us at cost effective prices.

Key Features:

  • Easy to fit
  • Hassle free functioning
  • Reliable operation
  • Sturdiness


Engineered for Extreme Cryogenic Conditions

Specifically designed to withstand exceptionally low temperatures, this cryogenic ball valve utilizes high-grade stainless steel and cryogenic-grade PTFE, ensuring reliability in the transfer of LNG and other cryogenic media. The anti-static and blow-out proof features provide operational safety, while the polished, cleaned surface guarantees minimal contamination and optimal performance in sensitive cryogenic processes.


Versatile End Connections and Automation Options

Available with flanged, butt weld, or socket weld connections, the valve can be easily integrated into a variety of cryogenic pipelines. The choice between double acting or spring return pneumatic actuators allows for precise control, while the automated mechanism simplifies operation and increases system efficiency.

FAQs of 2 Way Pneumatic Actuator Operated Cryogenic Ball Valve:


Q: How does the pneumatic actuator operate the cryogenic ball valve?

A: The valve is actuated automatically using either a double acting or spring return pneumatic actuator. Pressurized air moves the actuator, enabling rapid ON/OFF operation of the ball valve, which is essential for precise and safe control in cryogenic applications.

Q: What makes this cryogenic ball valve suitable for extremely low temperatures?

A: The investment cast stainless steel body, polished SS316 ball, and cryogenic-grade PTFE or reinforced PTFE seats are designed to perform reliably in cryogenic conditions, preventing leaks, sticking, and material brittleness at temperatures far below zero.

Q: When should a user choose flanged, butt weld, or socket weld end connections?

A: Flanged ends are ideal for easy installation and maintenance, butt weld ends provide a secure, leak-proof joint for high-integrity systems, and socket weld ends are preferred for smaller pipe sizes or where space is limited. The choice depends on the specific piping layout and service requirements.

Q: Where are these cryogenic ball valves typically used?

A: These valves are widely used in industries handling cryogenic liquids and gases, such as LNG plants, liquid nitrogen or oxygen distribution, hydrogen refueling stations, and industrial gas processing facilities, especially where automated flow control is required.

Q: What benefit does the stem extension provide in cryogenic service?

A: The stem extension ensures that the operational mechanism remains at a safe distance from the cold zone, minimizing the transfer of extreme low temperatures to the actuator and gland area. This preserves actuator efficiency and extends valve service life.

Q: How does the anti-static and blow-out proof design enhance safety?

A: The anti-static feature prevents the build-up of static electricity during operation, reducing ignition risks, while the blow-out proof stem ensures that the stem cannot be ejected from the valve body under high pressure, significantly increasing operational safety in hazardous environments.

Q: What is the process for maintaining this type of cryogenic ball valve?

A: Regular inspection is recommended, particularly for seals and actuator components. The polished and cleaned surfaces minimize icing and residue build-up, simplifying cleaning. Always follow the manufacturers maintenance guidelines to ensure long-term, leak-free performance in cryogenic environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cryogenic Valve Category

3  Way Pneumatic Operated Cryogenic Ball Valve

3 Way Pneumatic Operated Cryogenic Ball Valve

Minimum Order Quantity : 1 Set

Application : Cryogenic services such as LNG, Liquid Oxygen, Liquid Nitrogen, Liquid Argon, and other lowtemperature gases

Power : Other , Pneumatic Operated

Port Size : 1/2 inch to 8 inch (DN15 to DN200)

Structure : Other, 3 Way Floating Ball Valve, Full Bore, Extended Bonnet

Surface : Other, Polished / Shot Blasted Finish

2 Way Pneumatic Operated Cryogenic Ball Valve

2 Way Pneumatic Operated Cryogenic Ball Valve

Minimum Order Quantity : 1 Set

Application : For cryogenic liquids, LNG, LOX, LIN, LAR, CO2

Power : Pneumatic

Port Size : 1/2 inch to 6 inch (DN15 to DN150)

Structure : Other, Flanged or Screwed Ends, Full Bore Ball Valve

Surface : Other, Smooth, Polished Finish

Cryogenic Ball Valve

Cryogenic Ball Valve

Minimum Order Quantity : 1 Set

Application : Cryogenic Service (LNG, Liquid Nitrogen, Oxygen, Argon, etc.)

Power : Manual

Port Size : 1/2 inch to 8 inch

Structure : Other, Floating Ball

Surface : Other, Polished

2 Way Cryogenic Valve

2 Way Cryogenic Valve

Minimum Order Quantity : 1 Set

Application : Cryogenic Liquid and Gas Handling

Power : Manual

Port Size : 1/2 inch to 6 inch

Structure : Other, 2 Way

Surface : Other, Polished