3 Way Pneumatic Operated Cryogenic Ball Valve
3 Way Pneumatic Operated Cryogenic Ball Valve Specification
- Structure
- 3 Way Floating Ball Valve, Full Bore, Extended Bonnet
- Material
- Stainless Steel (SS 304/316) or Carbon Steel with extended stem and low-temperature service packing
- Power
- Pneumatic Operated
- Pressure
- Class 150 - 600 (10 to 100 Bar), custom ratings available
- Media
- Liquefied gases, Cryogenic fluids
- Working Temperature
- -196C to +80C (suitable for cryogenic applications)
- Port Size
- 1/2 inch to 8 inch (DN15 to DN200)
- Surface
- Polished / Shot Blasted Finish
- Shape
- 3 Way (T-Port or L-Port configuration)
- Application
- Cryogenic services such as LNG, Liquid Oxygen, Liquid Nitrogen, Liquid Argon, and other low-temperature gases
- Seat Material
- PTFE, RTFE, or PCTFE for low temperature
- Stem Extension Length
- As per cryogenic standards for vapor barrier and insulation
- End Connection
- Flanged (ASME, DIN), Screwed, or Butt-welded
- Body Design
- Full / Reduced Bore, Three-Piece or Two-Piece Construction
- Testing Standard
- Tested as per BS 6364 / API 598 for cryogenic valves
- Mounting Standard
- ISO 5211 for Direct Actuator Mounting
- Fire Safe Design
- Available as per API 607
- Leakage Class
- ANSI Class VI / Bubble Tight Shutoff
- Operation
- On/Off or Diverting/Divisional Service
- Actuator Type
- Double Acting or Spring Return Pneumatic Actuator
3 Way Pneumatic Operated Cryogenic Ball Valve Trade Information
- Minimum Order Quantity
- 1 Set
- Supply Ability
- 1000 Sets Per Day
- Delivery Time
- 1 Days
- Sample Available
- Yes
- Sample Policy
- Free samples are available
- Main Domestic Market
- All India
About 3 Way Pneumatic Operated Cryogenic Ball Valve
J. D. CONTROLS is the manufacturer of 3 Way Pneumatic Operated Cryogenic Ball Valve. feature a direct mount automation pad for electric and pneumatic actuators. The high quality investment castings feature a fully machined bore. The superior live-loaded packing system is accomplished with Belleville washers, V ring packing and a unique primary pyramidal stem seal. This advanced sealing system provides for protection against stem leaks experienced by ordinary ball valves
Automated with Pneumatic Spring Return Actuator
Automated with Pneumatic Double Acting Actuator
Automated with Electric Actuator
Robust Cryogenic Performance
Crafted for extreme low temperatures, the valve operates efficiently from -196C up to +80C. Its advanced stem extension and seat material optionsPTFE, RTFE, or PCTFEensure minimal leakage and reliable sealing even in demanding cryogenic services. The fire safe design and rigorous product testing add further assurance for critical applications.
Flexible Design Options
Choose from full or reduced bore, various construction types, and multiple end connections to suit bespoke requirements. Pneumatic actuators support both double acting and spring return operation, making the valve adaptable for On/Off or diverting services. The ISO 5211 mounting standard enables easy actuator integration and future upgrades.
FAQs of 3 Way Pneumatic Operated Cryogenic Ball Valve:
Q: How is the 3 Way Pneumatic Operated Cryogenic Ball Valve suited for cryogenic applications?
A: This valve features materials and design elements tailored to cryogenic fluids, including an extended stem for vapor barrier, compatible seat options like PTFE, RTFE, or PCTFE, and rigorous testing (BS 6364/API 598). These ensure safe, tight shutoff and performance in low temperatures down to -196C.Q: What actuator types are offered with this cryogenic ball valve?
A: The valve supports pneumatic actuators in either double acting or spring return configurations, allowing users to select the mechanism best suited for their On/Off or diverting operational requirements within automated process environments.Q: When should I use a bubble tight shutoff (ANSI Class VI) for my cryogenic service?
A: A bubble tight shutoff is essential when handling hazardous, costly, or sensitive cryogenic fluids where zero leakage is required for safety and operational integrity, as specified by ANSI Class VI standards.Q: Where can this valve be installedwhat end connection options are available?
A: The valve is adaptable for installation across various pipelines, offering flanged (ASME, DIN), screwed, or butt-welded end connections to accommodate different site requirements and international standards.Q: What is the process for mounting the pneumatic actuator to the valve?
A: Direct actuator mounting is facilitated through an ISO 5211 compliant pad, ensuring standardization, quick assembly, and reliable interface between the actuator and valve body for optimal automation.Q: How does the fire safe design benefit cryogenic applications?
A: Fire safe design per API 607 ensures the valve maintains shutoff integrity during fire incidents by using robust materials and construction details, which is vital for safety when managing flammable cryogenic media.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Cryogenic Valve Category
2 Way Pneumatic Operated Cryogenic Ball Valve
Minimum Order Quantity : 1 Set
Surface : Other, Smooth, Polished Finish
Application : For cryogenic liquids, LNG, LOX, LIN, LAR, CO2
Port Size : 1/2 inch to 6 inch (DN15 to DN150)
Pressure : Other, Up to 40 bar (dependent on model)
Structure : Other, Flanged or Screwed Ends, Full Bore Ball Valve
Cryogenic Ball Valve
Minimum Order Quantity : 1 Set
Surface : Other, Polished
Application : Cryogenic Service (LNG, Liquid Nitrogen, Oxygen, Argon, etc.)
Port Size : 1/2 inch to 8 inch
Pressure : High Pressure
Structure : Other, Floating Ball
2 Way Cryogenic Ball Valve Socket Weld End
Minimum Order Quantity : 1 Set
Surface : Other, Polished / Shot Blasted
Application : Cryogenic Service for LNG, Liquid Oxygen, Nitrogen, Argon, Hydrogen, etc.
Port Size : 1/2 to 8 (DN15 to DN200)
Pressure : Other, Up to 40 Bar (580 PSI)
Structure : Other, Floating Ball
2 Way Pneumatic Actuator Operated Cryogenic Ball Valve
Minimum Order Quantity : 1 Set
Surface : Other, Polished / Cleaned for Cryogenic Service
Application : Cryogenic Liquids, LNG, Liquid Nitrogen, Oxygen, Argon
Port Size : inch to 8 inch (DN15DN200)
Pressure : Other, Up to 20 bar (290 psi)
Structure : Other, Ball Valve
![]() |
J. D. CONTROLS
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |





Send Inquiry